What should a load notice show?
- The name of the racking manufacturer or supplier.
- The maximum load per beam level (per pair of beams) and how it is distributed.
- The maximum load per bay (frame to frame).
- The height to the first beam level and the spacing between levels for which these values apply.
- Any restrictions, such as pallet type or loading method.
The notice must be clearly visible, for example at the end of each run.
When is a load notice no longer valid?
A load notice only applies to the configuration it was calculated for. If beams are moved, levels added or different goods stored, the capacity may change. A new load notice is then needed, based on the manufacturer’s data.
Is that data missing, for example for old or second-hand racking? Then the capacity must first be determined by the manufacturer or a competent engineer.
What SESS Europe checks
During every racking inspection we check whether load notices are present and legible and whether the stated values match the actual configuration. A missing or incorrect load notice is recorded in the inspection report.
Need new or updated load notices? Contact us and we will look at what is needed. See also what to do after an impact or damage.
Last updated: 24 November 2026.
EN 15635 requires the maximum load to be clearly displayed on the racking. During an inspection a missing or incorrect load notice is recorded in the report.
Yes. If the spacing or number of levels changes, the capacity may change. The load notice must then be recalculated from the manufacturer’s data.
It must first be determined by the manufacturer or a competent engineer. Until then, load no more than necessary and have the racking inspected.
Make your warehouse a safe working environment
Do you want to make your warehouse a safe and reliable working environment for your employees? Do you want this in black and white on paper? Complete the form or contact us without obligation via the options below!
-
- KMO Zone AKMO
- Heideveld 2
- 9960 Assenede